| Sign In | Join Free | My gimpguru.org | 
 | 
Brand Name : JINSP
Model Number : SR100Q
Certification : ISO9001
Place of Origin : CHINA
MOQ : 1
Price : Negotiable
Payment Terms : T/T, Western Union
Supply Ability : 100PCS/90-120 days
Delivery Time : 90-120 working days
Packaging Details : International Shipping Pakcage
Spectrual Range : 200nm - 1100nm
Effective pixels : 1024*122
Qutuam Efficiency : QE92%peak@650nm, 83%@232nm
SNR : 1000:1
Critical to semiconductors, PV panels, and display tech, thin films require meticulous thickness monitoring. Photoelectric techniques revolutionize this process through harmless, high-speed measurements. Modern systems combine optical instruments with AI algorithms to optimize film production, ensuring superior quality while accelerating industrial advancement.
| Detector | Chip Type | Back-illuminated TE-cooled Hamamatsu S7031 | 
| Effective Pixel | 1024*122 | |
| Pixel Size | 24*24μm | |
| Sensing Area | 24.576*2.928mm | |
| Optical Parameters | Optical Design | F/4 cross-type | 
| Numerical Aperture | 0.13 | |
| Focal Length | 100mm | |
| Entrance Slit Width | 10μm,25μm,50μm,100μm,200μm (customizable) | |
| Fiber Interface | SMA905,free space | |
| Electrical Parameters | Integration Time | 8ms-3600s | 
| Data Output Interface | USB3.0,RS232,RS485,20pin connector | |
| ADC Bit Depth | 16-bit | |
| Power Supply | 5V | |
| Operating Current | <3.5A | |
| Physical Parameters | Operating Temperature | 10℃~40℃ | 
| Storage Temperature | -20℃~60℃ | |
| Operating Humidity | <90%RH (no condensation) | |
| Dimensions | 180mm*120mm*50mm | |
| Weight | 1.2kg | 
| Model | Spectral Range(nm) | Resolution(nm) | Slit(μm) | 
| SR100Q-G21 SR100Q-G22 | 200~950 350~1100 | 6.8 | 200 | 
| 2.2 | 50 | ||
| 1.5 | 25 | ||
| 1.0 | 10 | ||
| SR100Q-G23 SR100Q-G24 | 200~775 350~925 | 1.6 | 50 | 
| 1.0 | 25 | ||
| 0.7 | 10 | ||
| SR100Q-G25 | 532~690(4400cm-1*)* | 13cm-1 | 50 | 
| SR100Q-G26 | 638~800(3200cm-1)* | 10cm-1 | 25 | 
| SR100Q-G27 | 785~1050(3200cm-1)* | 11cm-1 | 50 | 
When light from the optical fiber probe strikes the film, dual reflections occur: one at the air-film surface and another at the film-substrate interface. The resulting beams interfere, producing spectral fringes detected by the spectrometer. The optical path difference enables thickness (d) determination using the extremum method, with inputs including θ, n, and spectral peaks. Thicker films exhibit tighter fringe spacing, whereas longer wavelengths spread them out. Measurement accuracy depends on appropriate wavelength and resolution settings.




JINSP Company Limited, abbreviated as "JINSP", is a professional supplier with over 17 years of experience in spectral detection technology products, including Raman, FT-IR, LIBS technologies, etc. After 17 years of technology accumulation, the company’s core key technologies have reached the international leading position at the level, and the cumulative number of patent applications exceeded 200.
In addition to its main headquarters located in the bustling city of Beijing, JINSP has established a fully owned subsidiary manufacturing facility situated in the province of Jiangsu, China.
JINSP Company received ISO9001:2015, ISO14001:2015, and ISO45001:2018 certifications. JINSP can provide required certifications, such as certification by the Ministry of Public Security or National Institute of Metrology, Environmental Level Certification, IP Level Certification, CE Certification, Transport Identification Report, EU ECAC certification, German ICT Security Testing, etc.



Q1:This is the first time I use, is it easy to operate?
A1:We will send you manual and guide vedio in English,it can teach you how to operate the spectrometer. Also our technicians will offer professional tecnical opearation meetings.
Q2: Can your offer a operation traning?
 A2: Your technicians can come to our factory for a training. Jinsp engineers can go to your place for local support
 ( installation, training, debugging, maintenance ).
Q3: What's your website?
 A3:You can visit:www.jinsptech.com
Q4: What about your quality assurance?
A4: We have a quality inspection team. All goods will go through quality inspection before shipment. We can send you pictures for inspection.
|   | 
| Accurate Film Thickness Measurement with F/4 Cross-Type Optical Design Fiber Optic Spectrometer Images | 
 Ultra High Sensitivity Fiber Optic Spectrometer SR100Q Back-Thinned scientific
                                                                                    
                        
                        
                        
                                                            Ultra High Sensitivity Fiber Optic Spectrometer SR100Q Back-Thinned scientific
                                                    
                        
                     Back-Thinned CCD Cooled Fiber Optic Spectrometer Module SR100Q For Scientific
                                                                                    
                        
                        
                        
                                                            Back-Thinned CCD Cooled Fiber Optic Spectrometer Module SR100Q For Scientific
                                                    
                        
                     SR100Q 92% High Quantum Efficiency CCD Modular Fiber Optic Spectrometer High SNR
                                                                                    
                        
                        
                        
                                                            SR100Q 92% High Quantum Efficiency CCD Modular Fiber Optic Spectrometer High SNR
                                                    
                        
                     SR100Q Back Thinned Modular Fiber Optic Spectrometer For Detect Absorption
                                                                                    
                        
                        
                        
                                                            SR100Q Back Thinned Modular Fiber Optic Spectrometer For Detect Absorption
                                                    
                        
                     Research Grade SR100Q CCD Fiber Optic Spectrometer Light Weight
                                                                                    
                        
                        
                        
                                                            Research Grade SR100Q CCD Fiber Optic Spectrometer Light Weight
                                                    
                        
                     SR100Q Back Thinned CCD Fiber Spectrometer High Signal-To-Noise Ratio Cooled
                                                                                    
                        
                        
                        
                                                            SR100Q Back Thinned CCD Fiber Spectrometer High Signal-To-Noise Ratio Cooled
                                                    
                        
                     Durable CCD Fiber Spectrometer Used In Scientific Research Lightweight
                                                                                    
                        
                        
                        
                                                            Durable CCD Fiber Spectrometer Used In Scientific Research Lightweight
                                                    
                        
                     Backlit Array CCD UV Enhanced High Sensitivity Modular Spectrometer with
                                                                                    
                        
                        
                        
                                                            Backlit Array CCD UV Enhanced High Sensitivity Modular Spectrometer with
                                                    
                        
                     Signal-To-Noise Ratio CCD Fiber Spectrometer Scientific Grade Low Noise
                                                                                    
                        
                        
                        
                                                            Signal-To-Noise Ratio CCD Fiber Spectrometer Scientific Grade Low Noise
                                                    
                        
                     180mm*120mm*50mm Size Back-illuminated Fiber Spectrometer with Integration Time
                                                                                    
                        
                        
                        
                                                            180mm*120mm*50mm Size Back-illuminated Fiber Spectrometer with Integration Time